Domestic Heat Pumps

  • Fluid Refrigerant : 134A
  • Compressor : Rotary Specially designed Heat pump specific compressors from HITACHI / TOSHIBA
  • Heat Exchanger: Built In High efficiency Tube in Shell Heat Exchanger
  • Electric power consumption: 650 W / 990 W
  • Heating temperature 55-60 Deg
Parameter VDHP 3000 MB VDHP 4500 MB VDHP 6000 MB VDHP 7500 MB VDHP 9000 MB VDHP 12000 MB
Hot Water Flow Rate (L/h)32446276.688.8117.6
Heating Capacity (kW)7.510.51518.52229.2
Rated water output @ 55°C (L/h)107015002142264231424171
Rated water output @ 60°C (L/h)97013711961242128713811
Rated water output @ 65°C (L/h)87312341764217925843431
Hot Water Outlet Temp (°C)55–6555–6555–6555–6555–6555–65
Rated Input Power (kW)2.33.24.55.56.58.6
Rated Input Current (A)3.54.86.88.510.214.0
Power Supply
Type220V / 1Phase / 50Hz
Compressor
TypeFully enclosed type
BrandPANASONIC / HITACHI / DANFOSS
Start MethodDirect Start
Quantity (No)111112
Water Proof GradeIP 24
Electric Shock Protection TypeI
Heat Exchanger
TypeHigh efficiency double wall heat exchanger
Quantity111112
MaterialMicro Groove Tube
EvaporatorHydrophilic Aluminum
RefrigerantR134aR134aR134aR407cR407cR407c
Expansion ValveSubmersive Sine Wave Electronic expansion valve
Water Side
Inlet Pipe Size (mm)252525404040
Outlet Pipe Size (mm)252525404040
Pipe TypeLow carbon copper pipe with hydrophilic foil
Fan
TypeHousehold
Speed (RPM)850
Input Power (W)303080808096
Quantity111112
Protections
Under / Over voltage protection, Under / Over current protection, Open phase, Phase reversal, Phase imbalance, Compressor high discharge temperature protection, Compressor high discharge pressure protection, Compressor over current protection, Anti-freeze protection
Noise (DBA)≤ 55DB(A)
Net Weight (kg)95100130160200270
CabinetGalvanized steel powder coated
Dimensions (mm)
Width9209201000125013001400
Depth520520560560600680
Height79079091091010101010

Commercial Heat Pumps

  • Fluid Refrigerant : R407c.
  • Compressor : Scroll Specially designed for Heat pump specific compressors from EMERSON COPELAND
  • Heat Exchanger: Built In High efficiency Tube in Shell
  • Electric power consumption: 650 W / 990 W